Capacidad nominal | 50N, 100N, 500N, 5kN, 20kN, 50kN, 100kN |
Salida a fondo de escala | Cap. ≤ 50N: 1.0mV/V ± 20%; Cap. > 50N: 2.0mV/V ± 20% |
Saldo cero | ± 0,02mV/V |
No linealidad | < ± 0.5% |
Repetibilidad | < ± 0.5% |
Error de histéresis | < ± 0.5% |
Creep en 30 minutos | < ± 0.5% |
Resistencia de entrada | 700Ω ±25Ω |
Resistencia de salida | 700Ω ± 3Ω |
Excitación recomendada | 10 V (15 V máximo) |
Resistencia del aislamiento | > 2GΩ (50V CC) |
Temperatura nominal | De -10°C a 40°C De 14°F a 104°F |
Sobrecarga segura | 150% del fondo de escala |
Romper la sobrecarga | 300% del fondo de escala |
Tipo de junta | Sellado ecológico |
Clasificación IP | IP66 |
296AS Botón de carga
Descripción:
Load buttons are compact force measurement solutions ideal for applications where weight and space conservation are top priorities. The 296AS stainless steel IP66 waterproof construction provides superior value without sacrificing reliability. Its innovative design allows a bolt to pass through vertically to measure compression force; a simple, compact, time-saving weighing solution.
Características:
- Material: Acero inoxidable
- Rated Capacities: 50N, 100N, 500N, 5kN, 20kN, 50kN, 100kN
- Full Scale Output: Cap. ≤ 50N: 1.0mV/V ± 20%; Cap. > 50N: 2.0mV/V ± 20%
- Safe Overload: 150% of full scale
- Breaking Overload: 300% of full scale
- Clasificación IP: IP66