{"id":964,"date":"2014-03-04T13:40:07","date_gmt":"2014-03-04T21:40:07","guid":{"rendered":"http:\/\/anyloadgroup.com\/?post_type=product&#038;p=964"},"modified":"2026-01-30T16:32:18","modified_gmt":"2026-01-31T00:32:18","slug":"a2p-load-cell-amplifier","status":"publish","type":"product","link":"https:\/\/www.anyload.com\/fr\/product\/a2p-load-cell-amplifier\/","title":{"rendered":"A2P Load Cell Amplifiers"},"content":{"rendered":"<p>ANYLOAD A2P series strain gage amplifiers provide load cell and transducer signal conditioning.\u00a0 The A2P series strain gage amplifiers are an AC or DC powered amplifiers that can drive up to 2 x 350\u03a9 load cells connected directly. They can also drive up to 4 x 350\u03a9 load cells or 8 x 700\u03a9 load cells through a junction box.\u00a0Equipped with individual adjustable resistors, the A2P is housed in a PVC enclosure and can be installed on a standard rail channel.\u00a0 Fully compliant with the Conformit\u00e9 Europ\u00e9enne (CE) &#8211; Electromagnetic Compatibility Directive, the A2P amplifier has a wide output signal of 0-10V or 4-20mA.<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"319\">Load Cell Type<\/td>\n<td valign=\"top\" width=\"319\">All strain gage types<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Alimentation \u00e9lectrique<\/td>\n<td valign=\"top\" width=\"319\">24V DC \u00b1 20% or AC95-250V<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Input Range<\/td>\n<td valign=\"top\" width=\"319\">0mV-30mV<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Maximum Power Voltage (DC)<\/td>\n<td valign=\"top\" width=\"319\">30V, 2.5A<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Maximum Power Voltage (AC)<\/td>\n<td valign=\"top\" width=\"319\">250V, 3A<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Output Signal<\/td>\n<td valign=\"top\" width=\"319\">0-10V<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Output Signal<\/td>\n<td valign=\"top\" width=\"319\">4mA-20mA \u00b1 20%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Maximum Output Signal<\/td>\n<td valign=\"top\" width=\"319\">30V<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Total Error<\/td>\n<td valign=\"top\" width=\"319\">0.02% of full scale<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Mat\u00e9riau du bo\u00eetier<\/td>\n<td valign=\"top\" width=\"319\">PVC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Indice de protection IP<\/td>\n<td valign=\"top\" width=\"319\">IP40<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Installation<\/td>\n<td valign=\"top\" width=\"319\">Standard rail channel<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-3944\" style=\"text-align: justify;\" src=\"\/wp-content\/uploads\/2014\/04\/pdf-.png\" alt=\"pdf-\" width=\"25\" height=\"25\" \/><span style=\"text-align: justify;\">\u00a0<a title=\"ANYLOAD | A2P Load Cell Amplifier\" href=\"https:\/\/www.anyload.com\/wp-content\/uploads\/2014\/03\/ANYLOAD-A2P-load-cell-amplifier.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Download data sheet for A2P<\/a><\/span><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-3944\" style=\"text-align: justify;\" src=\"\/wp-content\/uploads\/2014\/04\/pdf-.png\" alt=\"pdf-\" width=\"25\" height=\"25\" \/><span style=\"text-align: justify;\">\u00a0<a title=\"ANYLOAD | A2P Load Cell Amplifier\" href=\"http:\/\/www.anyload.com\/wp-content\/uploads\/2018\/01\/Anyload-A2P-D2-load-cell-amplifier.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Download data sheet for A2P-D2<\/a><\/span><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-3944\" style=\"text-align: justify;\" src=\"\/wp-content\/uploads\/2014\/04\/pdf-.png\" alt=\"pdf-\" width=\"25\" height=\"25\" \/><span style=\"text-align: justify;\">\u00a0<a title=\"ANYLOAD | A2P Load Cell Amplifier\" href=\"https:\/\/www.anyload.com\/wp-content\/uploads\/2019\/08\/Anyload-A2P-load-cell-amplifier.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Download data sheet for A2P-D2 &amp; A2P-D2B<\/a><\/span><\/p>\n<p><span style=\"text-align: justify;\"> <img decoding=\"async\" class=\"alignnone size-full wp-image-3944\" style=\"text-align: justify;\" src=\"\/wp-content\/uploads\/2014\/04\/pdf-.png\" alt=\"pdf-\" width=\"25\" height=\"25\" \/><span style=\"text-align: justify;\">\u00a0<a title=\"ANYLOAD | A2P Amplifier Manual\" href=\"http:\/\/www.anyload.com\/wp-content\/uploads\/2016\/11\/A2P-amplifier-manual-V1611.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Download\u00a0manual for A2P<\/a><\/span><\/span><\/p>\n<p><span style=\"text-align: justify;\"> <img decoding=\"async\" class=\"alignnone size-full wp-image-3944\" style=\"text-align: justify;\" src=\"\/wp-content\/uploads\/2014\/04\/pdf-.png\" alt=\"pdf-\" width=\"25\" height=\"25\" \/><span style=\"text-align: justify;\">\u00a0<a title=\"ANYLOAD | A2P-D2 Amplifier Manual\" href=\"http:\/\/www.anyload.com\/wp-content\/uploads\/2017\/04\/A2P-D2-amplifier-manual-V1704.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Download\u00a0manual for A2P-D2<\/a><\/span><\/span><\/p>\n<p style=\"text-align: justify;\"><img decoding=\"async\" class=\"alignnone size-full wp-image-3944\" src=\"\/wp-content\/uploads\/2014\/04\/pdf-.png\" alt=\"pdf-\" width=\"25\" height=\"25\" \/>\u00a0<a title=\"ANYLOAD | CE Certificate\" href=\"http:\/\/www.anyload.com\/wp-content\/uploads\/2016\/06\/A2P-EMC2016.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">CE Certificate &#8211;\u00a0Electromagnetic Compatibility Directive<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>ANYLOAD A2P series strain gage amplifiers provide load cell and transducer signal conditioning.\u00a0 The A2P series strain gage amplifiers are DC powered amplifiers that can drive up to 2 x 350\u03a9 load cells connected directly. They can also drive up to 4&#215;350\u03a9 or 8&#215;700\u03a9 or 8&#215;350\u03a9 load cells through a junction box.\u00a0Equipped with individual adjustable resistors, the A2P&#8217;s are housed in a PVC enclosure and can be installed on a standard rail channel.\u00a0 Fully compliant with the Conformit\u00e9 Europ\u00e9enne (CE) &#8211; Electromagnetic Compatibility Directive, the A2P amplifiers have wide input signal from 0\u00b136mV and output signal of 0\u00b110V or 4-20mA. The A2P-D2 amplifier is now equipped with two options of excitation voltages (5VDC or 12VDC) to comply the desired requirements in various applications.<\/p>","protected":false},"featured_media":22094,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[2386,23],"product_tag":[1474,1475,1473,1467,1468,1469,1470,1471,1472],"industries_product":[],"application_product":[],"class_list":{"0":"post-964","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-instrumentation","7":"product_cat-amplifiers","8":"product_tag-amplifier","9":"product_tag-amplifiers-2","10":"product_tag-analogue-load-cell-amplifier","11":"product_tag-load-cell-amplifier","12":"product_tag-load-cell-amplifiers","13":"product_tag-strain-gage-amplifier","14":"product_tag-strain-gage-amplifiers","15":"product_tag-strain-gauge-amplifier","16":"product_tag-strain-gauge-amplifiers","17":"pa_part-number-a2p-d2b","18":"pa_part-number-a2p-d2","19":"pa_part-number-a2p","20":"desktop-align-center","21":"tablet-align-left","22":"mobile-align-left","23":"ast-product-gallery-layout-horizontal-slider","24":"ast-product-gallery-with-no-image","25":"ast-magnify-disabled","26":"ast-product-single-variable","27":"ast-product-tabs-layout-horizontal","29":"first","30":"instock","31":"shipping-taxable","32":"purchasable","33":"product-type-variable"},"acf":[],"_links":{"self":[{"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/product\/964","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/media\/22094"}],"wp:attachment":[{"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/media?parent=964"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/product_brand?post=964"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/product_cat?post=964"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/product_tag?post=964"},{"taxonomy":"industries_product","embeddable":true,"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/industries_product?post=964"},{"taxonomy":"application_product","embeddable":true,"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/application_product?post=964"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}