{"id":693,"date":"2014-03-03T10:41:22","date_gmt":"2014-03-03T18:41:22","guid":{"rendered":"http:\/\/anyloadgroup.com\/?post_type=product&#038;p=693"},"modified":"2026-01-30T16:30:31","modified_gmt":"2026-01-31T00:30:31","slug":"a2a-load-cell-amplifier","status":"publish","type":"product","link":"https:\/\/www.anyload.com\/fr\/product\/a2a-load-cell-amplifier\/","title":{"rendered":"A2A-D2 Load Cell Amplifier"},"content":{"rendered":"<p>ANYLOAD A2A-D2 strain gauge amplifiers provide load cell and transducer signal conditioning.\u00a0 The A2A strain gage amplifier is AC and DC powered and can drive up to 4 x 350\u03a9 load cells or 8 x 700\u03a9 load cells.\u00a0 It can be connected directly to 1 or 2 load cells or connected to more than 2 load cells through a junction box.\u00a0 Equipped with individually adjustable resistors and an installation clamp for single-point fixing, the A2A strain gage amplifier is watertight with an aluminum casting enclosure and has a wide output signal of 0-10V or 4-20mA.<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"319\">Load Cell Type<\/td>\n<td valign=\"top\" width=\"319\">All strain gage types<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Alimentation \u00e9lectrique<\/td>\n<td valign=\"top\" width=\"319\">24V DC \u00b1 20%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Input Range<\/td>\n<td valign=\"top\" width=\"319\">0mV-30mV<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Maximum Power Voltage (DC)<\/td>\n<td valign=\"top\" width=\"319\">30V, 2.5A<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Maximum Power Voltage (AC)<\/td>\n<td valign=\"top\" width=\"319\">250V, 3A<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Output Signal<\/td>\n<td valign=\"top\" width=\"319\">0V-10V<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Output Signal<\/td>\n<td valign=\"top\" width=\"319\">4mA-20mA \u00b1 20%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Maximum Output Signal<\/td>\n<td valign=\"top\" width=\"319\">30V<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Total Error<\/td>\n<td valign=\"top\" width=\"319\">0.02% of full scale<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Mat\u00e9riau du bo\u00eetier<\/td>\n<td valign=\"top\" width=\"319\">Aluminum casting<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Indice de protection IP<\/td>\n<td valign=\"top\" width=\"319\">IP66<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"319\">Installation<\/td>\n<td valign=\"top\" width=\"319\">Single point fixing, Clamp fixing<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: justify;\"><img decoding=\"async\" class=\"alignnone size-full wp-image-3944\" src=\"\/wp-content\/uploads\/2014\/04\/pdf-.png\" alt=\"pdf-\" width=\"25\" height=\"25\" \/><a title=\"ANYLOAD | A2A Load Cell Amplifier\" href=\"https:\/\/www.anyload.com\/wp-content\/uploads\/2014\/03\/ANYLOAD-A2A-load-cell-amplifier.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">\u00a0Download data sheet for A2A<\/a><\/p>\n<p style=\"text-align: justify;\"><img decoding=\"async\" class=\"alignnone size-full wp-image-3944\" src=\"\/wp-content\/uploads\/2014\/04\/pdf-.png\" alt=\"pdf-\" width=\"25\" height=\"25\" \/><a title=\"ANYLOAD | A2A Load Cell Amplifier\" href=\"https:\/\/www.anyload.com\/wp-content\/uploads\/2019\/08\/Anyload-A2A-load-cell-amplifier.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">\u00a0Download data sheet for A2A-D2<\/a><\/p>\n<p style=\"text-align: justify;\"><img decoding=\"async\" class=\"alignnone size-full wp-image-3944\" src=\"\/wp-content\/uploads\/2014\/04\/pdf-.png\" alt=\"pdf-\" width=\"25\" height=\"25\" \/><a title=\"ANYLOAD | A2A Load Cell Amplifier\" href=\"http:\/\/www.anyload.com\/wp-content\/uploads\/2016\/11\/A2A-amplifier-manual-V1611.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">\u00a0Download manual<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>ANYLOAD A2A-D2 series strain gage amplifiers provide load cell and transducer signal conditioning.\u00a0 The A2A-D2 strain gage amplifiers are DC-powered amplifiers that can drive up to 2 x 350\u03a9 load cells connected directly. It can also drive several load cells up to 4 x 350\u03a9 load cells or 8 x 700\u03a9 load cells through a junction box. Equipped with individually adjustable resistors, the A2A-D2 strain gage amplifiers are watertight with an aluminum casting enclosure and have a wide input signal from 0\u00b136mV and an output signal of 0\u00b110V or 4-20mA. The A2A-D2 amplifier is now equipped with two options of excitation voltages (5VDC or 12VDC) to comply with the desired requirements in various applications.<\/p>","protected":false},"featured_media":22075,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[2386,23],"product_tag":[1474,1475,1473,1467,1468,1469,1470,1471,1472],"industries_product":[],"application_product":[3326,3327,3323,3328,3325,3324,3322],"class_list":{"0":"post-693","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-instrumentation","7":"product_cat-amplifiers","8":"product_tag-amplifier","9":"product_tag-amplifiers-2","10":"product_tag-analogue-load-cell-amplifier","11":"product_tag-load-cell-amplifier","12":"product_tag-load-cell-amplifiers","13":"product_tag-strain-gage-amplifier","14":"product_tag-strain-gage-amplifiers","15":"product_tag-strain-gauge-amplifier","16":"product_tag-strain-gauge-amplifiers","17":"pa_part-number-a2a-d2","18":"application_product-application-bench-products","19":"application_product-application-checkweighing-products","20":"application_product-application-low-capacity-hopper-products","21":"application_product-application-onboard-weighing-products","22":"application_product-application-overhead-weighing-products","23":"application_product-application-platform-products","24":"application_product-application-tank-silo-products","25":"desktop-align-center","26":"tablet-align-left","27":"mobile-align-left","28":"ast-product-gallery-layout-horizontal-slider","29":"ast-product-gallery-with-no-image","30":"ast-magnify-disabled","31":"ast-product-single-variable","32":"ast-product-tabs-layout-horizontal","34":"first","35":"instock","36":"shipping-taxable","37":"purchasable","38":"product-type-variable"},"acf":[],"_links":{"self":[{"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/product\/693","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/media\/22075"}],"wp:attachment":[{"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/media?parent=693"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/product_brand?post=693"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/product_cat?post=693"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/product_tag?post=693"},{"taxonomy":"industries_product","embeddable":true,"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/industries_product?post=693"},{"taxonomy":"application_product","embeddable":true,"href":"https:\/\/www.anyload.com\/fr\/wp-json\/wp\/v2\/application_product?post=693"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}